FS-1016Ex for process applications, EXPLOSION PROOF ENVIRONMENT

|
Unique and cost effective solution for monitoring the presence of organic and non-organic deposits in non-water industrial applications within explosion proof environment.
Fouling is a multibillion dollar problem, reducing energy efficiency, increasing maintenance costs and creating health risks.
Our approach consists in early, preventative, online monitoring with a standard output signal going either to a local controller or directly into the supervision system.
The FS-1016Ex probe continuously monitors the fouling trend inside the process lines, reactors or exchangers enabling the optimization of treatment and confirmation of treatments effectiveness.
Industries
» Chemical
» Energy
» Oil & gas
Benefits
· Real-time, continuous & in-situ monitoring of fouling in industrial processes
· Explosion proof
· Resistant to harsh environments
· No maintenance
Features
· Reduced operating costs
· Decreased chemical discharge
· Extended life of industrial equipment
|
GENERAL
|
|
Probe dimensions
|
d165mm (6,4 in) x L 334mm (13.2in)
|
|
Fittings & Connection
|
FLANGE DN50
|
|
Configuration
|
In-line or by-pass
|
|
Approval
|
ATEX CE EEx es II T4 II 3G – zone 2
|
|
Wetted material
|
316L SS
|
|
Protection class
|
IP66
|
|
Outputs
|
2 active analog outputs 4…20mA (max. 500W)
· 1 analog output for thickness monitoring (configurable range)
· 1 analog output for temperature measurement (fixed range)
|
|
Power supply
|
24Vdc / 100mA
|
|
|
|
SPECIFICATIONS
|
|
Fouling monitoring
|
Configurable monitoring ranges
|
Accuracy
|
|
0…1mm (0…0.039 in)
or
0…5mm (0…0.197 in)
|
±50mm
|
|
Temperature measurement
|
Fixed range
|
Accuracy
|
|
0…160°C (32…320°F)
|
±0.1°C (±0.2°F)
|
|
Running conditions
|
Temperature (stability)
|
Pressure
|
|
0…130°C max (<1°C/min)
32…266°F max (<1.8°F/min)
|
20 bars max.
290 psi max.
|
|
|
|
|
|
|